Output voltage is now wrong - off by about 220VΒ #1973

Closed

Description

@jonandel

Something is underreportng the output voltage of my UPS - Im sure it used to be correct, when I set it up about 18 months ago...
See below - input voltage is 230V, output 10.

I'm using NUT Tools in Homeassistant Hassos.

  • Homeassistant community addon Nut Tools.

NUT Tools config:

  • config: []
    driver: usbhid-ups
    name: myups
    port: auto
  • Home assistant Yaml showing NUT sensor for correct Powerwalker device.

sensor:

UPS PowerWalker Device

  • platform: nut
    name: "PowerWalker VI USB 6500"
    host: a0d7b954-nut
    username: !secret nutups_user
    password: !secret nutups_password
    resources:
    • battery.charge
    • battery.runtime
    • ups.load
    • ups.status
  • Homeassistant Integration showing data from the Nut Tools device - note seems to get the vendor and device type OK...
"integration_manifest": {
"domain": "nut",
"name": "Network UPS Tools (NUT)",
"codeowners": [
"@bdraco",
"@ollo69",
"@pestevez"
],
"config_flow": true,
"documentation": "https://www.home-assistant.io/integrations/nut",
"integration_type": "device",
"iot_class": "local_polling",
"loggers": [
"pynut2"
],
"requirements": [
"pynut2==2.1.2"
],
"zeroconf": [
"_nut._tcp.local."
],
"is_built_in": true
},
"data": {
"entry": {
"entry_id": "96848fcb81c918f44c4b066b12ebe4e1",
"version": 1,
"domain": "nut",
"title": "a0d7b954-nut:3493",
"data": {
"host": "a0d7b954-nut",
"port": 3493,
"password": "REDACTED",
"username": "REDACTED"
},
"options": {
"scan_interval": 60
},
"pref_disable_new_entities": false,
"pref_disable_polling": false,
"source": "user",
"unique_id": null,
"disabled_by": null
},
"nut_data": {
"ups_list": {
"myups": "Description unavailable"
},
"status": {
"battery.charge": "100",
"battery.charge.low": "10",
"battery.charge.warning": "20",
"battery.mfr.date": "1 ",
"battery.runtime": "2520",
"battery.runtime.low": "300",
"battery.type": "PbAcid",
"battery.voltage": "13.7",
"battery.voltage.nominal": "12",
"device.mfr": "1 ",
"device.model": " 650",
"device.serial": " ",
"device.type": "ups",
"driver.name": "usbhid-ups",
"driver.parameter.pollfreq": "30",
"driver.parameter.pollinterval": "2",
"driver.parameter.port": "auto",
"driver.parameter.synchronous": "auto",
"driver.version": "2.8.0",
"driver.version.data": "CyberPower HID 0.6",
"driver.version.internal": "0.47",
"driver.version.usb": "libusb-1.0.26 (API: 0x1000109)",
"input.frequency": "50.2",
"input.transfer.high": "290",
"input.transfer.low": "165",
"input.voltage": "241.3",
"input.voltage.nominal": "230",
"output.frequency": "50.2",
"output.voltage": "10.9",
"ups.beeper.status": "enabled",
"ups.delay.shutdown": "20",
"ups.delay.start": "30",
"ups.load": "12",
"ups.mfr": "1 ",
"ups.model": " 650",
"ups.productid": "0601",
"ups.realpower.nominal": "360",
"ups.serial": " ",
"ups.status": "OL",
"ups.timer.shutdown": "-60",
"ups.timer.start": "-60",
"ups.vendorid": "0764"
}
},......

I posted details in the HA Core - suggestion there that it may be a NUT tools/driver issue...hence posting here for ideas...
home-assistant/core#95157

Activity

  1. jonandel commented on Jun 25, 2023

    @jonandel
    Author

    I notice this in the addon log though - is it significant ?

    [10:34:42] INFO: Configuring Device named myups...
    [10:34:42] INFO: Starting the UPS drivers...
    **Network UPS Tools - Generic HID driver 0.47 (2.8.0)
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 65535 in ReportID: 0x0f
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x12
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x13**
    Using subdriver: CyberPower HID 0.6
    USB communication driver (libusb 1.0) 0.43
    Network UPS Tools - UPS driver controller 2.8.0
    cont-init: info: /etc/cont-init.d/nut.sh exited 0
    cont-init: info: running /etc/cont-init.d/nutclient.sh
    cont-init: info: /etc/cont-init.d/nutclient.sh exited 0
    s6-rc: info: service legacy-cont-init successfully started
    s6-rc: info: service legacy-services: starting
    services-up: info: copying legacy longrun upsd (no readiness notification)
    services-up: info: copying legacy longrun upsmon (no readiness notification)
    [10:34:42] INFO: Starting the UPS information server...
    
  2. added
    PowerWalkerPowerWalker and BlueWalker branded devices
    Home Assistant (HA)Use of NUT with third-party plugin for Home Assistant (HA)
    impacts-release-2.8.0Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)
    on Jun 26, 2023
  3. jimklimov commented on Jun 26, 2023

    @jimklimov
    Member

    Hello, thanks for the post. It may be significant - one of the changes in NUT v2.8.0 release was about detecting malformed protocol information and amending that (stemming from issue #1024 and later issues and PRs on this matter; another related thread is #439). Looking at related key words, I think #1969 is quite similar to yours (although there the bogus value is larger and does not change over time).

    It is possible that some of that did misfire and better amendments could have been made, so in the NUT master branch there were some fixes later, e.g. #1338 or #1497

  4. jonandel commented on Jul 1, 2023

    @jonandel
    Author

    thanks - yes I saw several that were similar - interestingly #1512 reports the same problem but with a slightly different product - - mine is a 650 with no LCD, rather than a 500 with LCD.
    However, I see NUT is reporting same vendor and product ID's....

  5. Dunuin commented on Aug 5, 2023

    @Dunuin

    Same problem here with my PowerWalker STL 800. Worked perfectly fine with latest NUT shipped with Debian 11, then I upgraded Debian to 12 and the output voltage directly dropped from ~235V to ~5V and is now fluctuating between 2V and 10V for 3 weeks.

  6. jimklimov commented on Aug 5, 2023

    @jimklimov
    Member

    Cheers, thanks for the reports. Are any of you in position to try custom-building NUT to query the device with current codebase (to check if this was solved after 2.8.0 release)? This can be done from a build workspace without compromising the packaged installation, see https://github.com/networkupstools/nut/wiki/Building-NUT-for-in%E2%80%90place-upgrades-or-non%E2%80%90disruptive-tests

  7. jonandel commented on Aug 19, 2023

    @jonandel
    Author

    Im running HASOS, so will need to pull out a rPi and setup a test rig....give me a week or so - and Ill give it a go.

  8. jonandel commented on Aug 21, 2023

    @jonandel
    Author

    Jim, Ive fired up a rPi and the master branch built (2.8.0.1)... which build do you suggest I try ?

  9. jimklimov commented on Aug 21, 2023

    @jimklimov
    Member

    I think master should do it for tests. And then fiddle with driver options: what it does by default now, if it reports better again or still wrong as in 2.8.0 vs. 2.7.4; I think there was a toggle to disable the fix for presumed bad usb logical min/max encoding... can't remember quickly now - but should be in man pages (to see if that is the culprit).

  10. jonandel commented on Aug 21, 2023

    @jonandel
    Author

    Erm OK. Remember though, I'm seeing the error in 2.8.0 pulled through in the Home Assistant add in an of about a month ago...but I don't know which version was used previously (which I don't think had the issue)....
    Let me play around for a few days..and ill come back....

  11. jimklimov commented on Aug 22, 2023

    @jimklimov
    Member

    Thanks! Note that Home Assistant builds generally include a version of NUT from packaging, e.g. Debian's 2.7.4 or 2.8.0 release plus their tweaks and backports over time. So even a 2.8.0 is a bit over a year old, and some fixes have landed since, and maybe something among these impacts the handling of your device.

    Thinking of it, you might want to build a custom HA plugin with current NUT. Never did that myself, but there is a contributed post on the Wiki about it.

  12. jonandel commented on Aug 28, 2023

    @jonandel
    Author

    Hey Jim, Im not quite sure what Im doing frankly - but I think I have the mast branch installed and running. (although tools such as nut-scanner complain about a missing libusb...
    anywhooo... when I probe with usb-hid-ups driver it seems to be communicating with the USB, and I get the below output.

    Is this any use? What should I do next ?

    pi@raspberrypi:~/nut $ sudo drivers/usbhid-ups -DD -u root -x explore -x vendorid=0764 -x port=auto -s ups
    Network UPS Tools - Generic HID driver 0.50 (2.8.0-2306-g3d9630e0f)
    USB communication driver (libusb 0.1) 0.44
       0.000005     [D1] Built-in default or configured user for drivers 'nobody' was ignored due to 'root' specified on command line
       0.000155     [D1] Network UPS Tools version 2.8.0-2306-g3d9630e0f (release/snapshot of 2.8.0.1) built with gcc (Raspbian 10.2.1-6+rpi1) 10.2.1 20210110 and configured with flags: --with-dev
       0.000208     [D1] debug level is '2'
       0.002482     [D1] Succeeded to become_user(root): now UID=0 GID=0
       0.002653     [D2] Initializing an USB-connected UPS with library libusb-0.1 (or compat) (NUT subdriver name='USB communication driver (libusb 0.1)' ver='0.44')
       0.002711     [D1] upsdrv_initups (non-SHUT)...
       0.075475     [D2] Checking device (1D6B/0003) (002/001)
       0.119071     [D2] - VendorID: 1d6b
       0.119141     [D2] - ProductID: 0003
       0.119200     [D2] - Manufacturer: Linux 6.1.21-v8+ xhci-hcd
       0.119257     [D2] - Product: xHCI Host Controller
       0.119314     [D2] - Serial Number: 0000:01:00.0
       0.119370     [D2] - Bus: 002
       0.119426     [D2] - Device: 001
       0.119483     [D2] - Device release number: 0601
       0.119540     [D2] Trying to match device
       0.119598     [D2] match_function_subdriver (non-SHUT mode): matching a device...
       0.119681     [D2] match_function_regex: failed match of VendorID: 1d6b
       0.119740     [D2] Device does not match - skipping
       0.120196     [D2] Checking device (0764/0601) (001/003)
       0.125553     [D2] - VendorID: 0764
       0.125620     [D2] - ProductID: 0601
       0.125675     [D2] - Manufacturer: 1
       0.125731     [D2] - Product:  650
       0.125788     [D2] - Serial Number:
       0.125844     [D2] - Bus: 001
       0.125900     [D2] - Device: 003
       0.125957     [D2] - Device release number: 0200
       0.126013     [D2] Trying to match device
       0.126070     [D2] match_function_subdriver (non-SHUT mode): matching a device...
       0.126172     [D2] Device matches
       0.126262     [D2] failed to claim USB device: could not claim interface 0: Device or resource busy
       0.127452     [D2] detached kernel driver from USB device...
       0.128336     [D2] Retrieved HID descriptor (expected 9, got 9)
       0.128454     [D2] HID descriptor length 739
       0.133944     [D2] Report Descriptor size = 739
       0.134557     HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 65535 in ReportID: 0x0f
       0.135343     HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x12
       0.135413     HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x13
       0.135822     Using subdriver: EXPLORE HID 0.2
       0.136607     [D1] 73 HID objects found
       0.139079     [D1] Path: UPS.PowerSummary.iProduct, Type: Feature, ReportID: 0x01, Offset: 0, Size: 8, Value: 1
       0.141339     [D1] Path: UPS.PowerSummary.iSerialNumber, Type: Feature, ReportID: 0x02, Offset: 0, Size: 8, Value: 2
       0.144096     [D1] Path: UPS.PowerSummary.iOEMInformation, Type: Feature, ReportID: 0x03, Offset: 0, Size: 8, Value: 3
       0.146844     [D1] Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x04, Offset: 0, Size: 8, Value: 4
       0.149587     [D1] Path: UPS.PowerSummary.Rechargeable, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 1
       0.152337     [D1] Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x06, Offset: 0, Size: 8, Value: 2
       0.155088     [D1] Path: UPS.PowerSummary.DesignCapacity, Type: Feature, ReportID: 0x07, Offset: 0, Size: 8, Value: 100
       0.155170     [D1] Path: UPS.PowerSummary.CapacityGranularity1, Type: Feature, ReportID: 0x07, Offset: 8, Size: 8, Value: 10
       0.155244     [D1] Path: UPS.PowerSummary.CapacityGranularity2, Type: Feature, ReportID: 0x07, Offset: 16, Size: 8, Value: 10
       0.155319     [D1] Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, ReportID: 0x07, Offset: 24, Size: 8, Value: 20
       0.155483     [D1] Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, ReportID: 0x07, Offset: 32, Size: 8, Value: 100
       0.155685     [D1] Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x07, Offset: 40, Size: 8, Value: 10
       0.158093     [D1] Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
       0.158177     [D1] Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
       0.158254     [D1] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x08, Offset: 8, Size: 16, Value: 2520
       0.158368     [D1] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x08, Offset: 8, Size: 16, Value: 2520
       0.158569     [D1] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
       0.158828     [D1] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
       0.160580     [D1] Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 12
       0.161329     [D1] Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x0a, Offset: 0, Size: 16, Value: 13.7
       0.162076     [D1] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0b, Offset: 0, Size: 1, Value: 1
       0.162154     [D1] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Input, ReportID: 0x0b, Offset: 1, Size: 1, Value: 1
       0.162226     [D1] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Input, ReportID: 0x0b, Offset: 2, Size: 1, Value: 0
       0.162331     [D1] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Input, ReportID: 0x0b, Offset: 3, Size: 1, Value: 0
       0.162527     [D1] Path: UPS.PowerSummary.PresentStatus.FullyCharged, Type: Input, ReportID: 0x0b, Offset: 4, Size: 1, Value: 1
       0.162728     [D1] Path: UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired, Type: Input, ReportID: 0x0b, Offset: 5, Size: 1, Value: 0
       0.162916     [D1] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x0b, Offset: 0, Size: 1, Value: 1
       0.163067     [D1] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x0b, Offset: 1, Size: 1, Value: 1
       0.163253     [D1] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x0b, Offset: 2, Size: 1, Value: 0
       0.163376     [D1] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x0b, Offset: 3, Size: 1, Value: 0
       0.163666     [D1] Path: UPS.PowerSummary.PresentStatus.FullyCharged, Type: Feature, ReportID: 0x0b, Offset: 4, Size: 1, Value: 1
       0.163933     [D1] Path: UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired, Type: Feature, ReportID: 0x0b, Offset: 5, Size: 1, Value: 0
       0.164828     [D1] Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 2
       0.165711     [D1] Path: UPS.PowerSummary.iManufacturer, Type: Feature, ReportID: 0x0d, Offset: 0, Size: 8, Value: 3
       0.168346     [D1] Path: UPS.Input.ConfigVoltage, Type: Feature, ReportID: 0x0e, Offset: 0, Size: 16, Value: 230
       0.171086     [D1] Path: UPS.Input.Voltage, Type: Feature, ReportID: 0x0f, Offset: 0, Size: 16, Value: 245.5
       0.173838     [D1] Path: UPS.Input.LowVoltageTransfer, Type: Feature, ReportID: 0x10, Offset: 0, Size: 16, Value: 165
       0.176592     [D1] Path: UPS.Input.HighVoltageTransfer, Type: Feature, ReportID: 0x11, Offset: 0, Size: 16, Value: 290
       0.179338     [D1] Path: UPS.Input.Frequency, Type: Feature, ReportID: 0x1c, Offset: 0, Size: 16, Value: 50.2
       0.182088     [D1] Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: 15.1
       0.184874     [D1] Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x13, Offset: 0, Size: 8, Value: 12
       0.187574     [D1] Path: UPS.Output.Test, Type: Feature, ReportID: 0x14, Offset: 0, Size: 8, Value: 0
       0.190324     [D1] Path: UPS.Output.DelayBeforeShutdown, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: -60
       0.193069     [D1] Path: UPS.Output.DelayBeforeStartup, Type: Feature, ReportID: 0x16, Offset: 0, Size: 16, Value: -60
       0.195818     [D1] Path: UPS.Output.Boost, Type: Feature, ReportID: 0x17, Offset: 0, Size: 1, Value: 0
       0.195941     [D1] Path: UPS.Output.Overload, Type: Feature, ReportID: 0x17, Offset: 1, Size: 1, Value: 0
       0.196051     [D1] Path: UPS.Output.Buck, Type: Feature, ReportID: 0x17, Offset: 2, Size: 1, Value: 0
       0.198569     [D1] Path: UPS.Output.ConfigActivePower, Type: Feature, ReportID: 0x18, Offset: 0, Size: 16, Value: 360
       0.201316     [D1] Path: UPS.Output.Frequency, Type: Feature, ReportID: 0x1d, Offset: 0, Size: 16, Value: 50.2
       0.204067     [D1] Path: UPS.Output.CommunicationLost, Type: Feature, ReportID: 0x1b, Offset: 0, Size: 8, Value: 0
       0.206827     [D1] Path: UPS.ff010004.ff010024.ff0100d0, Type: Feature, ReportID: 0x19, Offset: 0, Size: 8, Value: 0.1
       0.209575     [D1] Path: UPS.ff010004.ff010024.ff0100d1, Type: Feature, ReportID: 0x1a, Offset: 0, Size: 8, Value: 0
       0.212325     [D1] Path: UPS.ff01001d.ff010019.ff010020, Type: Feature, ReportID: 0x25, Offset: 0, Size: 1, Value: 0
       0.215074     [D1] Path: UPS.ff01001d.ff010019.ff010021, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 1, Value: 0
       0.215198     [D1] Path: UPS.ff01001d.ff010019.ff010021, Type: Input, ReportID: 0x2c, Offset: 0, Size: 1, Value: 0
       0.217820     [D1] Path: UPS.ff01001d.ff01001a.ff010001, Type: Feature, ReportID: 0x26, Offset: 0, Size: 1, Value: 0
       0.220567     [D1] Path: UPS.ff01001d.ff01001a.ff010002, Type: Feature, ReportID: 0x27, Offset: 0, Size: 8, Value: 1
       0.223335     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.223468     [D1] Can't retrieve Report 28: Value too large for defined data type
       0.223580     [D1] Path: UPS.ff01001d.ff01001b.ff010040, Type: Feature, ReportID: 0x28, Offset: 0, Size: 8
       0.224423     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.224543     [D1] Can't retrieve Report 28: Value too large for defined data type
       0.224674     [D1] Path: UPS.ff01001d.ff01001b.ff010016, Type: Input, ReportID: 0x28, Offset: 0, Size: 8
       0.225549     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.225664     [D1] Can't retrieve Report 28: Value too large for defined data type
       0.225777     [D1] Path: UPS.ff01001d.ff01001b.ff010018, Type: Feature, ReportID: 0x28, Offset: 8, Size: 8
       0.226875     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.227018     [D1] Can't retrieve Report 28: Value too large for defined data type
       0.227132     [D1] Path: UPS.ff01001d.ff01001b.ff010018, Type: Input, ReportID: 0x28, Offset: 8, Size: 8
       0.229587     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.229730     [D1] Can't retrieve Report 29: Value too large for defined data type
       0.229843     [D1] Path: UPS.ff01001d.ff01001b.ff010015, Type: Feature, ReportID: 0x29, Offset: 0, Size: 8
       0.230827     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.230960     [D1] Can't retrieve Report 29: Value too large for defined data type
       0.231071     [D1] Path: UPS.ff01001d.ff01001b.ff010015, Type: Output, ReportID: 0x29, Offset: 0, Size: 8
       0.231936     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.232058     [D1] Can't retrieve Report 29: Value too large for defined data type
       0.232173     [D1] Path: UPS.ff01001d.ff01001b.ff010017, Type: Feature, ReportID: 0x29, Offset: 8, Size: 8
       0.233034     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.233154     [D1] Can't retrieve Report 29: Value too large for defined data type
       0.233264     [D1] Path: UPS.ff01001d.ff01001b.ff010017, Type: Output, ReportID: 0x29, Offset: 8, Size: 8
       0.239493     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.239632     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.239748     [D1] Path: UPS.ff01001d.ff01001b.ff010010, Type: Feature, ReportID: 0x2d, Offset: 0, Size: 1
       0.240556     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.240680     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.240793     [D1] Path: UPS.ff01001d.ff01001b.ff01001e, Type: Feature, ReportID: 0x2d, Offset: 1, Size: 1
       0.241671     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.241790     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.241899     [D1] Path: UPS.ff01001d.ff01001b.ff01001f, Type: Feature, ReportID: 0x2d, Offset: 2, Size: 1
       0.242830     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.242960     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.243073     [D1] Path: UPS.ff01001d.ff01001b.ff010010, Type: Input, ReportID: 0x2d, Offset: 0, Size: 1
       0.243928     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.244048     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.244158     [D1] Path: UPS.ff01001d.ff01001b.ff01001e, Type: Input, ReportID: 0x2d, Offset: 1, Size: 1
       0.244927     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.245044     [D1] Can't retrieve Report 2d: Value too large for defined data type
       0.245154     [D1] Path: UPS.ff01001d.ff01001b.ff01001f, Type: Input, ReportID: 0x2d, Offset: 2, Size: 1
       0.246085     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.246204     [D1] Can't retrieve Report 2a: Value too large for defined data type
       0.246492     [D1] Path: UPS.ff01001d.ff01001b.ff010013, Type: Feature, ReportID: 0x2a, Offset: 0, Size: 1
       0.247320     [D2] libusb_get_report: error sending control message: Value too large for defined data type
       0.247444     [D1] Can't retrieve Report 2b: Value too large for defined data type
       0.247554     [D1] Path: UPS.ff01001d.ff01001b.ff010014, Type: Feature, ReportID: 0x2b, Offset: 0, Size: 1
       0.247713     [D2] Report descriptor retrieved (Reportlen = 739)
       0.247815     [D2] Found HID device
       0.247918     [D1] Detected a UPS: 1 / 650
       0.248030     [D2] find_nut_info: unknown info type: load.off.delay
       0.248131     [D2] find_nut_info: unknown info type: load.on.delay
       0.248231     [D2] find_nut_info: unknown info type: load.off.delay
       0.248374     [D1] upsdrv_initinfo...
       0.248539     [D1] upsdrv_updateinfo...
       0.250090     [D1] Got 3 HID objects...
       0.250227     [D2] Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
       0.250513     [D2] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x08, Offset: 8, Size: 16, Value: 2340
       0.250632     [D2] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
       0.250739     [D1] Quick update...
       0.254045     [D2] dstate_init: sock /var/state/ups/usbhid-ups-ups open on fd 5
       0.254353     [D1] Group and/or user account for this driver was customized ('root:nogroup') compared to built-in defaults. Fixing socket '/var/state/ups/usbhid-ups-ups' ownership/access.
       0.254552     [D1] Group access for this driver successfully fixed
       0.254706     Running as foreground process, not saving a PID file
       0.254834     [D1] Driver initialization completed, beginning regular infinite loop
       0.254954     [D1] upsdrv_updateinfo...
       1.005626     [D2] libusb_get_interrupt: Connection timed out
       1.005687     [D1] Got 0 HID objects...
       1.005718     [D1] Quick update...
       2.256235     [D1] upsdrv_updateinfo...
       2.273343     [D1] Got 6 HID objects...
       2.273391     [D2] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0b, Offset: 0, Size: 1, Value: 1
       2.273432     [D2] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Input, ReportID: 0x0b, Offset: 1, Size: 1, Value: 1
       2.273469     [D2] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Input, ReportID: 0x0b, Offset: 2, Size: 1, Value: 0
       2.273505     [D2] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Input, ReportID: 0x0b, Offset: 3, Size: 1, Value: 0
       2.273542     [D2] Path: UPS.PowerSummary.PresentStatus.FullyCharged, Type: Input, ReportID: 0x0b, Offset: 4, Size: 1, Value: 1
       2.273579     [D2] Path: UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired, Type: Input, ReportID: 0x0b, Offset: 5, Size: 1, Value: 0
       2.273609     [D1] Quick update...
       4.258242     [D1] upsdrv_updateinfo...
       4.259609     [D1] Got 3 HID objects...
       4.259658     [D2] Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
       4.259700     [D2] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x08, Offset: 8, Size: 16, Value: 2580
       4.259735     [D2] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
       4.259767     [D1] Quick update...
       6.260321     [D1] upsdrv_updateinfo...
       6.261994     [D1] Got 6 HID objects...
       6.262105     [D2] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0b, Offset: 0, Size: 1, Value: 1
       6.262201     [D2] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Input, ReportID: 0x0b, Offset: 1, Size: 1, Value: 1
       6.262353     [D2] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Input, ReportID: 0x0b, Offset: 2, Size: 1, Value: 0
       6.262450     [D2] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Input, ReportID: 0x0b, Offset: 3, Size: 1, Value: 0
       6.262542     [D2] Path: UPS.PowerSummary.PresentStatus.FullyCharged, Type: Input, ReportID: 0x0b, Offset: 4, Size: 1, Value: 1
       6.262633     [D2] Path: UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired, Type: Input, ReportID: 0x0b, Offset: 5, Size: 1, Value: 0
       6.262712     [D1] Quick update...
       8.262347     [D1] upsdrv_updateinfo...
       8.279230     [D1] Got 3 HID objects...
       8.279333     [D2] Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
       8.279431     [D2] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x08, Offset: 8, Size: 16, Value: 2400
       8.279525     [D2] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
       8.279601     [D1] Quick update...
      10.264396     [D1] upsdrv_updateinfo...
      10.281533     [D1] Got 6 HID objects...
      10.281642     [D2] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0b, Offset: 0, Size: 1, Value: 1
      10.281737     [D2] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Input, ReportID: 0x0b, Offset: 1, Size: 1, Value: 1
      10.281832     [D2] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Input, ReportID: 0x0b, Offset: 2, Size: 1, Value: 0
      10.281921     [D2] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Input, ReportID: 0x0b, Offset: 3, Size: 1, Value: 0
      10.282009     [D2] Path: UPS.PowerSummary.PresentStatus.FullyCharged, Type: Input, ReportID: 0x0b, Offset: 4, Size: 1, Value: 1
      10.282097     [D2] Path: UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired, Type: Input, ReportID: 0x0b, Offset: 5, Size: 1, Value: 0
      10.282173     [D1] Quick update...
      12.266427     [D1] upsdrv_updateinfo...
      12.283767     [D1] Got 3 HID objects...
      12.283872     [D2] Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x08, Offset: 0, Size: 8, Value: 100
      12.283965     [D2] Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x08, Offset: 8, Size: 16, Value: 2220
      12.284053     [D2] Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, ReportID: 0x08, Offset: 24, Size: 16, Value: 300
      12.284128     [D1] Quick update...
    
  13. jonandel commented on Aug 28, 2023

    @jonandel
    Author

    PS, any ideas why this doesnt work ? Whats the subdriver ?

    (I used the quoted subdriver thats 'discovered' too - no luck 'EXPLORE HID 0.2'

    xx@raspberrypi:~/nut $ sudo ./drivers/nutdrv_qx -s tempups -d1 -DDDDDD -x port=auto -x vendorid=0764 -x productid=0601 -x subdriver="CyberPower HID 0.6"
    Network UPS Tools - Generic Q* USB/Serial driver 0.33 (2.8.0-2306-g3d9630e0f)
    USB communication driver (libusb 0.1) 0.44
       0.000004     [D3] main_arg: var='port' val='auto'
       0.000341     [D6] testinfo_reloadable: var=port, infoname=driver.parameter.port, newval=auto, reloadable=0, reload_flag=0
       0.000397     [D6] testinfo_reloadable: verdict for (re)loading var=port value: 1
       0.000463     [D5] send_to_all: SETINFO driver.parameter.port "auto"
       0.000937     [D3] main_arg: var='vendorid' val='0764'
       0.001016     [D5] send_to_all: SETINFO driver.parameter.vendorid "0764"
       0.001072     [D3] main_arg: var='productid' val='0601'
       0.001495     [D5] send_to_all: SETINFO driver.parameter.productid "0601"
       0.001553     [D3] main_arg: var='subdriver' val='CyberPower HID 0.6'
       0.001619     [D5] send_to_all: SETINFO driver.parameter.subdriver "CyberPower HID 0.6"
       0.002058     [D1] Network UPS Tools version 2.8.0-2306-g3d9630e0f (release/snapshot of 2.8.0.1) built with gcc (Raspbian 10.2.1-6+rpi1) 10.2.1 20210110 and configured with flags: --enable-check-NIT
       0.002124     [D1] debug level is '6'
       0.002186     [D5] send_to_all: SETINFO driver.debug "6"
       0.002243     [D5] send_to_all: SETFLAGS driver.debug RW NUMBER
       0.005496     [D1] Succeeded to become_user(nobody): now UID=65534 GID=65534
       0.005588     [D5] send_to_all: SETINFO device.type "ups"
       0.005650     [D5] send_to_all: SETINFO driver.state "init.device"
       0.005703     [D1] upsdrv_initups...
       0.006128     Subdriver 'CyberPower HID 0.6' not found!
       0.006203     [D5] send_to_all: SETINFO driver.state "cleanup.exit"
    pi@raspberrypi:~/nut $
    
  14. jimklimov commented on Aug 29, 2023

    @jimklimov
    Member

    Try usbhid-ups without the -x explore flag (it discovers and reports known data points to help write new sub-drivers, but does not interpret them).

    At least, according to the initial report the device was handled with usbhid-ups which is about a different protocol than what nutdrv_qx uses (that said, its subdriver would be like plain cyberpower - single token, without versions).

  15. jonandel commented on Aug 31, 2023

    @jonandel
    Author

    ok done... not sure it particularly helpful... gives the same as nutdrv_qx...:

    pi@raspberrypi:~/nut $ sudo ./drivers/usbhid-ups -s 0764 -x port=auto
    Network UPS Tools - Generic HID driver 0.50 (2.8.0-2306-g3d9630e0f)
    USB communication driver (libusb 0.1) 0.44
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 65535 in ReportID: 0x0f
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x12
    HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x13
    Using subdriver: CyberPower HID 0.8
    ...
    
  16. jonandel commented on Aug 31, 2023

    @jonandel
    Author

    either way - it shows the current Master has the same problem as reported: ie

    0.171086 [D1] Path: UPS.Input.Voltage, Type: Feature, ReportID: 0x0f, Offset: 0, Size: 16, Value: **245.5**
    0.182088 [D1] Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: **15.1**
    

    So probably confirmed its still a problem !

    However, the logmax is less than statments appear to apply to the reportID's corresponding to the output voltage (at least word 0x12) - so perhaps IS related to that in the code....

  17. jonandel commented on Sep 3, 2023

    @jonandel
    Author

    @jimklimov Any ideas where to start looking ? I see the cyberpower driver was updated about a year ago - but I dont see those HID Report desciptors having changed.
    I pulled the patest mast yesterday - as I see a few changes to the cyberpower-mib recently. I rebuilt, but still get the same incorrect reporting value for output voltage.
    Also, in my original post, the sub-driver version is being reported as "driver.version.data": "CyberPower HID 0.6" - but current version here is 0.54 ... Where should I start looking ?

  18. jimklimov commented on Dec 18, 2024

    @jimklimov
    Member

    PR #2718 is presumed to have fixed the broken CPS input/output voltage reports mentioned in this issue.

  19. added this to the 2.8.3 milestone on Dec 18, 2024
  20. added
    Incorrect or missing readingsOn some devices driver-reported values are systemically off (e.g. x10, x0.1, const+Value, etc.)
    on Dec 18, 2024
  21. jonandel commented on Dec 19, 2024

    @jonandel
    Author

    Great news ! thanks to all !
    I have to admit I gave up after tinkering for a while, and packed away my rPi dev machine.
    Now I only have to wait until Home Assistant Code team integrate these changes !

  22. jimklimov commented on Dec 19, 2024

    @jimklimov
    Member

    There's a wiki article about building your own HA plugin... I don't use it yet, so can't help directly.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    CyberPower (CPS)Home Assistant (HA)Use of NUT with third-party plugin for Home Assistant (HA)Incorrect or missing readingsOn some devices driver-reported values are systemically off (e.g. x10, x0.1, const+Value, etc.)PowerWalkerPowerWalker and BlueWalker branded devicesUSBbugimpacts-release-2.8.0Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)

    Type

    No type

    Projects

    Milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions